<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://eln.excellgen.com/index.php?action=history&amp;feed=atom&amp;title=Adenovirus_Purification_by_Chromatography</id>
	<title>Adenovirus Purification by Chromatography - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://eln.excellgen.com/index.php?action=history&amp;feed=atom&amp;title=Adenovirus_Purification_by_Chromatography"/>
	<link rel="alternate" type="text/html" href="https://eln.excellgen.com/index.php?title=Adenovirus_Purification_by_Chromatography&amp;action=history"/>
	<updated>2026-10-18T04:03:32Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.44.0</generator>
	<entry>
		<id>https://eln.excellgen.com/index.php?title=Adenovirus_Purification_by_Chromatography&amp;diff=21077&amp;oldid=prev</id>
		<title>Paul.xu at 00:12, 8 July 2020</title>
		<link rel="alternate" type="text/html" href="https://eln.excellgen.com/index.php?title=Adenovirus_Purification_by_Chromatography&amp;diff=21077&amp;oldid=prev"/>
		<updated>2020-07-08T00:12:28Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;1. 48 hours after infection, spin down cells.&amp;lt;br/&amp;gt;2. Resuspend cell pellet in 10 ml of resuspension buffer (5 mM Tris–HCl, 75 mM NaCl, 1 mM MgCl2 , 5% sucrose, 1% Polysorbate-80 (PS-80), pH 8.0)&lt;br /&gt;
&lt;br /&gt;
3. Transfer into two 50-ml conical tubes (∼25 ml each).&amp;lt;br/&amp;gt;4. Freeze the tubes at –70 oC for at least 1 h. The frozen harvested cells can be held indefinitely at this point.&amp;lt;br/&amp;gt;5. Thaw the tubes in a 37 °C water bath.&amp;lt;br/&amp;gt;6. Repeat steps 3 and 4 two times.&lt;br /&gt;
&lt;br /&gt;
7. Centrifuge cell lysate for 10 min at 9000 × g.&amp;lt;br/&amp;gt;8. Collect the supernatant and transfer to another bottle.&amp;lt;br/&amp;gt;9. Add Benzonase to a final concentration of 150 U/ml, mixing thoroughly&amp;lt;br/&amp;gt;10. Incubate 1 h at room temperature with gentle mixing on a stir plate, (or overnight at 4 oC).&amp;lt;br/&amp;gt;11. Concentrate virus by Diafiltration/ultrafiltration using 50 cm2 300 kDa regenerated cellulose tangential flow ultrafiltration cartridge and Diafiltration buffer: 50 mM HEPES, 2 mM MgCl2 , 1 M NaCl, pH 7.5.&lt;br /&gt;
&lt;br /&gt;
12. Pack a column with 8 ml of Source 15Q resin.&amp;lt;br/&amp;gt;13. Sanitize the column using 0.1 N NaOH though the column at 1.2 ml/min until the pH is elevated in the effluent. Disconnect the column and hold in NaOH for 30 min.&amp;lt;br/&amp;gt;14. Wash with buffer B.&amp;lt;br/&amp;gt;15. Wash with buffer A.&amp;lt;br/&amp;gt;16. Equilibrate column with 5 CV (40 ml) of buffer A at 1.2 ml/min.&amp;lt;br/&amp;gt;17. Load samples to column at 1.2 ml/min.&amp;lt;br/&amp;gt;18. Wash column with 5 CV (40 ml) of buffer A&amp;lt;br/&amp;gt;19. Elute adenovirus using a linear gradient to 100% buffer B over 4 column volumes. The virus peak will have an A260/A280 ratio of approximately 1.25, and the adenovirus should elute in approximately 1–1.5-column volumes&amp;lt;br/&amp;gt;20. Pre-equilibrate 1 PD-10 desalting column (GE Healthcare PD-10) for each 2.5 ml of batch volume, using 25 ml of stabilizing buffer (5 mM Tris–HCl, 75 mM NaCl, 1 mM MgCl2 , 5% sucrose, 0.005% PS-80, pH 8.0).&amp;lt;br/&amp;gt;21. Allow column to drain completely. If virus will not be applied to the column within about 5 min, recap so that the column will not dry out.&amp;lt;br/&amp;gt;22. Within a biosafety cabinet, pipette 2.5 ml of virus fraction on each column, and allow to drain.&amp;lt;br/&amp;gt;23. Add 3.5 ml of stabilizing buffer and collect this fraction as product.&amp;lt;br/&amp;gt;24. Pool the product fractions.&amp;lt;br/&amp;gt;25. Inside a biosafety cabinet, carefully draw the product into a luer-lock syringe.&amp;lt;br/&amp;gt;26. Attach a sterile 0.22 μm PVDF Millex GV-25 syringe filter.&amp;lt;br/&amp;gt;27. Slowly push the product through the filter. If resistance increases, replace the filter and continue&lt;br /&gt;
&lt;br /&gt;
Adjustment buffer: 50 mM HEPES, 2 mM MgCl2 , 0.1% Polysorbate-80, pH 7.5.&amp;lt;br/&amp;gt;Chromatography buffer A: 50 mM HEPES, 2 mM MgCl2 , 0.39 M NaCl, 0.1% Polysorbate-80, pH 7.5 (see Note 6).&amp;lt;br/&amp;gt;Chromatography buffer B: 50 mM HEPES, 2 mM MgCl2 , 0.47 M NaCl, 0.1% Polysorbate-80, pH 7.5&amp;lt;br/&amp;gt;Diafiltration buffer: 50 mM HEPES, 2 mM MgCl2 , 1 M NaCl, pH 7.5.&amp;lt;br/&amp;gt;Resuspension buffer: 5 mM Tris–HCl, 75 mM NaCl, 1 mM MgCl2 , 5% sucrose, 1% Polysorbate-80 (PS-80), pH 8.0.&lt;br /&gt;
&lt;br /&gt;
Note: The capacity of 8 ml 15Q column: the column can be used to process 10^13 vp.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
== Purification of Adenovirus, 2020 ==&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Category:Protocols]]&lt;/div&gt;</summary>
		<author><name>Paul.xu</name></author>
	</entry>
</feed>