<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://eln.excellgen.com/index.php?action=history&amp;feed=atom&amp;title=Plasmid_Membrane_Chromatography</id>
	<title>Plasmid Membrane Chromatography - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://eln.excellgen.com/index.php?action=history&amp;feed=atom&amp;title=Plasmid_Membrane_Chromatography"/>
	<link rel="alternate" type="text/html" href="https://eln.excellgen.com/index.php?title=Plasmid_Membrane_Chromatography&amp;action=history"/>
	<updated>2026-10-18T21:19:35Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.44.0</generator>
	<entry>
		<id>https://eln.excellgen.com/index.php?title=Plasmid_Membrane_Chromatography&amp;diff=6536&amp;oldid=prev</id>
		<title>Paul.xu at 03:08, 14 October 2012</title>
		<link rel="alternate" type="text/html" href="https://eln.excellgen.com/index.php?title=Plasmid_Membrane_Chromatography&amp;diff=6536&amp;oldid=prev"/>
		<updated>2012-10-14T03:08:56Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;Qiagen column:&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Qiagen resins allow a tight binding of&amp;lt;br&amp;gt;pDNA molecules. Thus, while at lower ionic strength (&amp;amp;lt;1.0 M&amp;lt;br&amp;gt;NaCl) the proteins and RNA are washed away, pDNA elutes&amp;lt;br&amp;gt;only at high salt conditions (1.6 M NaCl, pH 7.0)&amp;lt;br&amp;gt;&amp;lt;br&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The bacterial cell paste (typically 200 g) was re-suspended in 2.4 L of a buffer containing 61 mM glucose, 10 mM Tris–HCL, and 50 mM EDTA, at pH 8. Bacteria were lysed using a previously described procedure.4 The clarified lysate was concentrated five times on a tangential flow filtration (TFF) system (nominal molecular weight cutoff 100,000 kDa, 0.1 m2 ). All experiments were conducted keeping a constant transmembrane pressure (TMP) of 0.8 bar at 4 °C, using Sartocon Slice equipment (Sartorius-Stedim Biotech). To remove RNA, the concentrated clarified lysate was loaded on Sepharose CL 4B in a BPG 113 column equilibrated with 20 mM Tris–HCL, 3 mM EDTA, and 1.5 M (NH4)2 SO4, at pH 7.2. &lt;br /&gt;
&lt;br /&gt;
Plasmid capture and elution using the Sartobind membrane was carried out after buffer exchange on a G25 matrix using 25 mM Tris, 10 mM EDTA, and 0.5 M NaCl, at pH 8 and a rate of 50 mL/min, to reach a conductivity of 45 ms/cm. The pDNA fraction was pumped at 150 mL/min to the membrane holder 91-D-01K-15-03. After loading the feeding solution, the membrane was rinsed with a pH 8 buffer containing 25 mM Tris, 10 mM EDTA, and 0.7 M NaCl. Bound plasmid DNA was eluted with a buffer solution containing 25 mM Tris, 10 mM EDTA, and 1.2 M NaCl at pH 8. Finally, the membrane was regenerated using 0.5 M NaOH. The pDNA polishing was achieved on Sephacryl S-1000 media on a formulation buffer of 20 mM NaH2PO4–Na2HPO4, 1 mM EDTA, and 30 mM NaCl at pH 6.7, using a 50X K column (Amersham BioSciences) at 4.8 mL/min. Fractions containing more than 89% supercoiled pDNA were processed by TFF until reaching a concentration of 2 mg/mL as determined by the absorbance at 260, using a VivaFlow 200 system (nominal molecular weight cutoff 100,000 kDa, 200 cm2 ). The final pDNA was filtered (0.22 μm) before further analyses were performed. &amp;lt;br&amp;gt; &lt;br /&gt;
&lt;br /&gt;
[[Category:Protocols]]&lt;/div&gt;</summary>
		<author><name>Paul.xu</name></author>
	</entry>
</feed>