<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://eln.excellgen.com/index.php?action=history&amp;feed=atom&amp;title=Purification_of_DNA_Binding_Protein_using_Heparin_Sepharose</id>
	<title>Purification of DNA Binding Protein using Heparin Sepharose - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://eln.excellgen.com/index.php?action=history&amp;feed=atom&amp;title=Purification_of_DNA_Binding_Protein_using_Heparin_Sepharose"/>
	<link rel="alternate" type="text/html" href="https://eln.excellgen.com/index.php?title=Purification_of_DNA_Binding_Protein_using_Heparin_Sepharose&amp;action=history"/>
	<updated>2026-10-19T06:27:44Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.44.0</generator>
	<entry>
		<id>https://eln.excellgen.com/index.php?title=Purification_of_DNA_Binding_Protein_using_Heparin_Sepharose&amp;diff=19910&amp;oldid=prev</id>
		<title>Paul.xu at 15:27, 5 March 2019</title>
		<link rel="alternate" type="text/html" href="https://eln.excellgen.com/index.php?title=Purification_of_DNA_Binding_Protein_using_Heparin_Sepharose&amp;diff=19910&amp;oldid=prev"/>
		<updated>2019-03-05T15:27:28Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;Performing a separation Heparin Sepharose 6 Fast Flow, Heparin Sepharose High Performance&lt;br /&gt;
&lt;br /&gt;
Binding buffer: 20 mM Tris-HCl, pH 8.0 or 10 mM sodium phosphate, pH 7.0 Elution buffer: 20 mM Tris-HCl, 1 to 2 M NaCl, pH 8.0 or 10 mM sodium phosphate, 1 to 2 M NaCl, pH 7.0 Equilibrate the column with 10 CV of binding buffer. Apply the sample. Wash with 5 to 10 CV of binding buffer or until no material appears in the eluent (monitored by UV absorption at A280 nm). Elute with 5 to 10 CV of elution buffer using a continuous or step gradient from 0% to 100% elution buffer. Modify the selectivity of heparin by altering pH or ionic strength of the buffers. Elute using a continuous or step gradient with NaCl, KCl or (NH4)2SO4 up to 2 M.&lt;br /&gt;
&lt;br /&gt;
If used for puriﬁcation or removal of coagulation factors:&lt;br /&gt;
&lt;br /&gt;
Since the heparin acts as an afﬁnity ligand for coagulation factors, it is advisable to include a minimum concentration of 150 mM NaCl in the binding buffer.&lt;br /&gt;
&lt;br /&gt;
If an increasing salt gradient gives unsatisfactory results, use heparin (1 to 5 mg/ml) as a competing agent in the elution buffer.&lt;br /&gt;
&lt;br /&gt;
Cleaning Remove ionically bound proteins by washing with 0.5 CV of 2 M NaCl for 10 to 15 min.&lt;br /&gt;
&lt;br /&gt;
Remove precipitated or denatured proteins by washing with 4 CV of 100 mM NaOH for 1 to 2 h; or 2 CV of 6 M guanidine hydrochloride for 30 to 60 min; or 2 CV of 8 M urea for 30 to 60 min. Remove hydrophobically bound proteins by washing with 4 CV of 0.1% to 0.5% Tween 20 for 1 to 2 h.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Chemical stability 100 mM NaOH (1 w at 20°C), 50 mM sodium acetate, pH 4.0, 4 M NaCl, 8 M urea, 6 M guanidine hydrochloride.&lt;br /&gt;
[[Category:Protocols]]&lt;/div&gt;</summary>