Editing
TEV Purification
(section)
Jump to navigation
Jump to search
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
=== Purification<br> === Buffers:<br>Buffer A: 20 mM phosphate, pH 7.5, 500 mM NaCl and 0.3 mM <span style="background-color: navy; color: white;" />beta-ME. <br>Buffer B: 20 mM phosphate, pH 7.5, 350 mM NaCl, 500 mM imidazole and 0.3 mM <span style="background-color: navy; color: white;" />beta-ME.<br>Buffer C: 10 mM Tris, pH 7.5, 0.3 mM <span style="background-color: navy; color: white;" />beta-ME. <br>Buffer D: 10 mM Tris, pH 7.5, 1 M NaCl and 0.3 mM beta-ME. <br> <br> 1. Suspend cell paste in 50 mM phosphate, pH 7.5, containing 300 mM NaCl, 20% ethylene glycol, 1 mM EDTA and 0.3 mM beta-ME at a ratio of 6 mL of buffer per g of wet cell paste. (34 g cells + 200 ml buffer) 2. Sonicate cell suspension for 6 min at 4 °C. 3. Spin for 25 min at 95,000 × g. 4. Load to 2 X 5 ml Ni HisTrap HP column pre-equilibrated with buffer A at 3 mL/min. 5. Was columns with eight volumes of a mixture of 85% buffer A and 15% buffer B (7.5 mM imidazole) at 5 mL/min. 6. Elute TEV with 100% buffer B at 0.7 mL/min. 7. Eluate is loaded to the second purifier with two 5 mL '''SP Fast Flow''' columns arranged in series at 0.7 mL/min. The columns were equilibrated with buffer C. The sample from the first purifier was injected into the mixing chamber mixed with 100% buffer C at 10 mL/min and loaded onto the columns of purification system 2 at a total flow rate of 10.7 mL/min. The resultant ~15-fold dilution of the sample prior to application to the cation exchange columns ensured that the ionic strength was low enough allow tight binding of the protease to the column.Upon completion of the IMAC elution, the flow through purifier system 1 was increased to 5 mL/min and directed to waste for column wash and reequilibration with buffer A prior to the injection of the next aliquot of lysate. The waste sample was collected so that possible losses of TEV protease could be determined. <br> 8. flow through purifier system 2 was decreased to 5 mL/min and a six column volume gradient from 100% buffer C to a mixture of 40% buffer C and 60% buffer D was started. Yield: ~400 mg per L of expression culture with >99% purity<br><br>
Summary:
Please note that all contributions to ELN may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
ELN:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Navigation menu
Personal tools
Not logged in
Talk
Contributions
Create account
Log in
Namespaces
Page
Discussion
English
Views
Read
Edit
View history
More
Search
Navigation
Category:
Main page
To Do
Tasks
My ELN
Weekly Reports
Buffer Recipe
SOP
Protocols
Inventories
Projects
Products
Customers
Contacts
Suppliers
Vectors
Vector Map
Clones
Cloning
Sequencing
NGS
Protein Expression
Purchaseing
QC
293 Expression
CHO Expression
Sf9 Expression
Protein Purification
Stem Cells
Cytokines
Protein Kinases
GPCR
Cell Lines
Competent Cells
Viral Proteins
VLP
Baculovirus
AAV
Adenovirus
Lentivirus
Virus Titering
Antibodies
Transfection
ELISA
qPCR RT-PCR
ImmunoAssay
Multiplex BioAssa
Lateral_Flow
Conjugation
Compounds Synthesis
BioEngineering
GenomeEngineering
Services
Software
Ideas
Links
Knowledgebase
Employees
Company
Tools
What links here
Related changes
Page information
Navigation
Special pages