MS 6 15 2017

From ELN
Revision as of 19:17, 15 June 2017 by Crm (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Troubleshoot the low flow speed problem of Ni column. Wash Ni column (bind with 1483 T4 DNA Ligase) with Ni washing buffer.

Elute QHP column (load with 1498 Taq DNA Ligase)

RTENOTITLE


Run SDS-PAGE gel of 1497 ToughTaq  7.40/72.2 06/15/2017

Number

1

2

3

4

5

6

7

8

9

10

11

12

sample

22

23

25

MW

26

27

28

29

30

31

33

35

uL

3.5

0.7

2.7

10

2.2

3.0

2.2

2.4

2.2

1.6

2.2

4.6

ddH2O

10

15

10

\

10

10

10

10

10

15

10

10

RTENOTITLE

Forward sample 22~24 to the next step.  

Prepare Buffer A.


Run SDS-PAGE gel of 1498 Taq DNA Ligase  6.56 / 79.1 06/15/2017

Number

1

2

3

4

5

6

7

8

9

10

11

12

sample

20

22

23

24

26

27

MW

28

29

32

35

39

uL

4.8

0.8

0.3

0.2

0.6

0.9

10

0.8

0.7

1.4

2.7

4.2

ddH2O

10

15

15

15

15

15

\

15

15

15

10

10

 

Forward sample 37~39 to the next step.

Dialysis. 1946 TdT bovine, 3.3mg/ml, 2.0ml, 6.6mg. Store at -80oC, 1-1-2 (Enzyme 2017)