Elisa protocol
Indirect ELISA
[edit]Protocol 1
[edit]
Reagents
[edit]
1. Coating BufferAnhydrous Na2CO 3 , 1.5 g
Anhydrous NaHCO3, 2.93 g
Distilled water, 1 liter, pH to 9.6
For an alternative coating buffer use ELISA coating buffer (BUF030)2. Blocking bufferPhosphate Buffered Saline (PBS) containing 1% w/v BSA
For an alternative blocking buffer, use either ELISA BSA Block (BUF032), ELISA Ultrablock (BUF033), or ELISA Synblock (BUF034)3. Wash bufferPhosphate Buffered Saline containing 0.05% v/v Tween®-20
For an alternative wash buffer use ELISA wash buffer (BUF031)Recommended Substrates and Stop SolutionsTMB Core+ (BUF062), for use with HRP-conjugated antibodies. Stop with 2M H2SO4.
pNPP (BUF044), for use with alkaline phosphatase-conjugated antibodies. Stop with 1M NaOH.
Method
[edit]Coat microtiter plate wells with 100 µl of the antigen solution, at a concentration of between 1-10 µg/ml in coating buffer. Cover the plate and incubate overnight at 4°C. Wash the plate 3 times in wash buffer.
Add 150 µl of blocking solution to each well. Incubate for 1 hour at 37°C. Wash 4 times in wash buffer.
Add 100 µl of unconjugated detection antibody (appropriately diluted in wash buffer) to each well. Incubate for 1 hour at 37°C. Wash 3 times in wash buffer.
Add 100 µl enzyme-conjugated secondary antibody (appropriately diluted in wash buffer) to each well. Incubate for 1 hour at 37°C. Wash 3 times in wash buffer.
Add 100 µl of the appropriate substrate solution to each well. Incubate at room temperature (and in the dark if required) for 30 minutes, or until desired color change is attained.
Read absorbance values immediately at the appropriate wavelength or add 50 µl of “stop solution”. Gently tap plate to ensure thorough mixing. Measure absorbance within 30 minutes.
Protocol 2
[edit]Coating antigen to microplate
[edit]Dilute the antigen to a final concentration of 20 µg/ml in PBS or other carbonate buffer. Coat the wells of a PVC microtiter plate with the antigen by pipetting 50 µl of the antigen dilution in the top wells of the plate. Dilute down the plate as required.
Test samples containing pure antigen are usually pipetted onto the plate at less than 2 µg/ml. Pure solutions are not essential, but as a guideline, over 3% of the protein in the test sample should be the target protein (antigen). Antigen protein concentration should not be over 20 µg/ml as this will saturate most of the available sites on the microtiter plate.
Ensure the samples contain the antigen at a concentration that is within the detection range of the antibody.
Cover the plate with an adhesive plastic and incubate for 2 hr at room temperature, or 4°C overnight. The coating incubation time may require some optimization.
Remove the coating solution and wash the plate three times by filling the wells with 200 µl PBS. The solutions or washes are removed by flicking the plate over a sink. The remaining drops are removed by patting the plate on a paper towel.
Blocking
[edit]Block the remaining protein-binding sites in the coated wells by adding 200 µl blocking buffer, 5% non-fat dry milk or 5% serum in PBS, per well.
Alternative blocking reagents include blockACE or BSA.
Cover the plate with an adhesive plastic and incubate for at least 2 hr at room temperature or, if more convenient, overnight at 4°C.
Wash the plate twice with PBS.
For antigen conjuated to BSA, use 5% non-fat dry milk in PBS, 1 g dry mick in 20 ml PBS, enough for 1 96 well plate
Incubate with serum
[edit]Aliquote 120 ul of PBS to each well in 96 well plate
Add 1.2 ul of serum to A1, mix by brief votexing; transfer 12 ul of A1 to A2, mix by brief votexing transfer 12 ul of A2 to A3
| A1 | 1:100 | 1.2 ul of serum |
| A2 | 1:1,000 | 12 ul of 1: 100 |
| A3 | 1:10,000 | 12 ul of 1:1,000 |
Cover the plate with an adhesive plastic and incubate for 2 hr at room temperature.
Incubation with primary and secondary antibody
[edit]Add 100 µl of diluted primary antibody to each well.
Cover the plate with an adhesive plastic and incubate for 2 hr at room temperature.
This incubation time may require optimization. Although 2 hr is usually enough to obtain a strong signal, if a weak signal is obtained, stronger staining will often be observed when incubated overnight at 4°C.
Wash the plate four times with PBS.
Add 100 µl of conjugated secondary antibody, diluted at the optimal concentration (according to the manufacturer) in blocking buffer immediately before use.
Cover the plate with an adhesive plastic and incubate for 1-2 hr at room temperature.
Wash the plate four times with PBS.
Detection
[edit]Although many different types of enzymes have been used for detection, horse radish peroxidase (HRP) and alkaline phosphatase (ALP) are the two widely used enzymes employed in ELISA assay. It is important to consider the fact that some biological materials have high levels of endogenous enzyme activity (such as high ALP in alveolar cells, high peroxidase in red blood cells) and this may result in non-specific signal. If necessary, perform an additional blocking treatment with levamisol (for ALP) or with 0.3% solution of H2O2 in methanol (for peroxidase).
ALP substrate
For most applications pNPP (p-Nitrophenyl-phosphate) is the most widely used substrate. The yellow color of nitrophenol can be measured at 405 nm after 15-30 min incubation at room temperature. (This reaction can be stopped by adding equal volume of 0.75 M NaOH).
HRP chromogens
The substrate for HRP is hydrogen peroxide. Cleavage of hydrogen peroxide is coupled to oxidation of a hydrogen donor which changes color during reaction.
TMB (3,3',5,5'-tetramethylbenzidine)
Add TMB solution to each well, incubate for 15-30 min, add equal volume of stopping solution (2 M H2SO4) and read the optical density at 450 nm.
OPD (o-phenylenediamine dihydrochloride)
The end product is measured at 492 nm. Be aware that the substrate is light sensitive so keep and store it in the dark.
ABTS (2,2'-azino-di-[3-ethyl]-bensothiazoline-6 sulfonic acid) diammonium salt.
The end product is green and the optical density can be measured at 416 nm.
Some enzyme substrates are considered hazardous (potential carcinogens), therefore always handle with care and wear gloves.
Dispense 100 µl (or 50 µl) of the substrate solution per well with a multichannel pipette or a multipipette.
After sufficient color development (if it is necessary) add 100 µl of stop solution to the wells.
Read the absorbance (optical density) of each well with a plate reader.