HTNCre HIC Purification
Date:2012-3-1
[edit]column:HiTrap phenylFF(low sub)
[edit]protein:HTNCre
[edit]
Method 1:
[edit]1.Equlibrate column with buffer 2M (NH4)2SO4 +20mM Tris-HCl
2.Load sample 0.5ml buffer (2M (NH4)2SO4 +20mM Tris-HCl) +0.5ml sample
3.Wash colume with 5 ml buffer 2M (NH4)2SO4 +20mM Tris-HCl into 10 tubes
4.Elute with 8 ml 1*PBS/10%glycerol into 4 tubes
5.Test protein with Brandford to observe which tube protein is in
result: 10 wash tubes -no protein
4 elute tubes - have protein, especially in the first tube, the fourth tube hardly has protein,protein can be eluted completely with 4 column volume elute buffer
Method 2(high salt condition):
[edit]1.Equlibrate column with buffer 2M (NH4)2SO4 +20mM Tris-HCl
2.Load sample 0.5ml buffer (2M (NH4)2SO4 +20mM Tris-HCl) +0.5ml sample
3.Wash colume with 5 ml buffer 2M (NH4)2SO4 +20mM Tris-HCl into 5 tubes
4.Washcolume with 5 ml buffer 2M NaCl/20mM Tris-HCl /10%glycerol into 5 tubes
5.Wash colume with 5 ml buffer 1M NaCl/20mM Tris-HCl /10%glycerol into 5 tubes
4.Elute with 5 ml 1*PBS/10%glycerol into 5 tubes
5.Test protein with Brandford to observe which tube protein is in
result: protein all exist in last 10 wash wells and 5 elute wells, but very little in each well,protein lose too much ,this method can not be used for protein purification